Chemistry
http://www.ibiblio.org/kuphaldt/socratic/sinst/book/liii_1v36.pdf
See PDF Pages 241-298
(57 pages total)
Instrumentation and Electrical Educational Resources. Note these resources are not mine I just collect them for educational use.
col·lab·o·ra·tion
kəˌlabəˈrāSHən/
noun
noun: collaboration; plural noun: collaborations
1.
the action of working with someone to produce or create something.
(Or in this case help each other)
Invite me or e-mail me the link of your info so I can place it on the blog. The Primary purpose of
Facebook, Google Drive, & gmail as well as this blog is used for this primary purpose
(Or in this case help each other)
Invite me or e-mail me the link of your info so I can place it on the blog. The Primary purpose of
Facebook, Google Drive, & gmail as well as this blog is used for this primary purpose
Saturday, October 5, 2013
Thursday, October 3, 2013
Hart Communicator Test with RTD & Thermocouple
Basic Concept of Hart PDF page 1024
http://www.ibiblio.org/kuphaldt/socratic/sinst/book/liii_1v36.pdf
(be willing to wait just a moment file size is large)
Ibid: PDF page 1435 about RTDs ,1443 about sensor connections
Ibid: PDF page 1447 about thermocouples, 1450 Types, 1469 about temp indicator connected to one.
Key Terms for Hart Communicator Test
http://www.ibiblio.org/kuphaldt/socratic/sinst/book/liii_1v36.pdf
(be willing to wait just a moment file size is large)
Ibid: PDF page 1435 about RTDs ,1443 about sensor connections
Ibid: PDF page 1447 about thermocouples, 1450 Types, 1469 about temp indicator connected to one.
Key Terms for Hart Communicator Test
- Calibration
- (1)A test during which known values of pressure are applied to the
transducer and corresponding output readings are recorded under
specified conditions.
(2)The matching of a pressure controller or
indicator to the characteristics of a specific transducer. Most
frequently done utilizing span resistor internal to the pressure
transducer. Procedure is termed RCal.
(3)Adjustment of an instrument to
standards of known accuracy and stability. (http://www.viatran.com/glossary#C)
Calibrationis used to perform such operations asperforming a sensor trim, D/A trim, and scaled D/A trim. (Hart 375 Manual PDF page 53)
Loop test
is used to set the output of the device at aspecified analog value, and may be used to test the integrity of the loop and the operation of indicators, recorders, or similar devices in the loop. (Hart 375 Manual PDF page 53) - Reranging
- A procedure allowing the modifications of configuration values and
parameters that change the transmitter 4-20 mA output settings in
response to input pressure readings.(http://www.viatran.com/glossary#R)
- Sensor Trim
- A digital trim procedure which permits the adjustment of a digital
process variable to a precisely known input pressure. Zero Trim and
Full Trim are the two Sensor Trim functions.(http://www.viatran.com/glossary#S)
Questions:
- What does the Dry Block Calibrator do? ___ , ___
- How does the RTD calibrator Simulate the Temperature scale?
- How does the thermocouple calibrator change the temperature scale setting? (Ex: betwxt K, J , T )
My answer: By pressing the store button
Derrick TassinOctober 6, 2013 at 12:58 PMTo change the temperature scale setting for the thermocouple calibrator, on the service manuel it says to use the dip switches, and to change t/c type to use the scroll button.
____ is always the negative ____
My answer: (concerning thermocouples)
the red , wire is always negative
Pressure & Level Class Labs
About the Differential Pressure Transmitter PDF Page 1261
http://www.ibiblio.org/kuphaldt/socratic/sinst/book/liii_1v36.pdf
Hart 275 Manual ***Link
HART communicator connection points Communicator loop resistance video
http://www.ibiblio.org/kuphaldt/socratic/sinst/book/liii_1v36.pdf
Hart 275 Manual ***Link
Rosemount 3051 Reference Manual
Rerange (pfd p. 54) The Range Values
command sets each of the lower and upper range analog
values (4 and 20 mA points and 1 and 5
Vdc points) to a pressure. The lower
range point represents 0% of range and
the upper range point represents
100% of range. In practice, the
transmitter range values may be changed as
often as necessary to reflect changing
process requirements. For a complete
listing of Range & Sensor limits,
refer to “Range and Sensor Limits” on
page A-4.
NOTE
Transmitters are shipped from Emerson
Process Management fully calibrated
per request or by the factory default
of full scale (zero to upper range limit).
NOTE
Regardless of the range points, the
3051 will measure and report all readings
within the digital limits of the sensor.
For example, if the 4 and 20 mA points
are set to 0 and 10 inH2O, and the
transmitter detects a pressure of 25 inH2O,
it digitally outputs the 25 inH2O
reading and a 250% of range reading.
P.56
Reranging using the Field Communicator
and applied pressure is a way of
reranging the transmitter when
specific 4 and 20 mA points (1 and 5 Vdc
points) are not calculated.
Sensor
Trim
P. 80
Sensor Trim Overview
Trim
the sensor using either sensor or zero trim functions. Trim functions vary
in
complexity and are application-dependent. Both trim functions alter the
transmitter’s
interpretation of the input signal.
…
Sensor trim is a two-point sensor calibration where two end-point pressures
Sensor trim is a two-point sensor calibration where two end-point pressures
are applied, and all output is
linearized between them. Always adjust the low
trim value first to establish the
correct offset. Adjustment of the high trim value
provides a slope correction to the
characterization curve based on the low
trim value. The trim values allow you
to optimize performance over your
specified measuring range at the calibration temperature.
See next page--à
ANALOG OUTPUT TRIM --------(Digital-to-Analog Trim)
p. 77
The Analog Output Trim commands allow
you to adjust the transmitter’s
current output at the 4 and 20 mA (1
and 5 Vdc) points to match the plant
standards. This command adjusts the digital to analog
signal conversion.
Zero Trim 275 Hart Communicator---
HART sensor trim upper 275
HART communicator connection points Communicator loop resistance video
- Read this PDF on JouleDeadweight Tester
- *operating instructions start on p. 20
Friday, September 27, 2013
RTD/ Thermocouple Calibration
Click link below to view calibration procedure
Hart 275 Communicator Manual *Link
Hart 375 Communicator Manual *Link
https://docs.google.com/file/d/0B4VZxTBlmecNOVJ3eFh2QVBJQWs/edit?usp=sharing
Note** Model 3144 TT navigation diagram to access snsr trim select snsr trim, but on
Model 644 TT select Scaled D/A Trim to get to snsr trim (sensor trim)
Hart 275 Communicator Manual *Link
- Generic online menu tree (PDF page 29)
Hart 375 Communicator Manual *Link
- Glossary PDF Page 105
https://docs.google.com/file/d/0B4VZxTBlmecNOVJ3eFh2QVBJQWs/edit?usp=sharing
Note** Model 3144 TT navigation diagram to access snsr trim select snsr trim, but on
Model 644 TT select Scaled D/A Trim to get to snsr trim (sensor trim)
picture: Below attachment for Model 3144 Temperature Transmitter.
![]() |
| 250 Ohm Resistor attached to negative terminal to power supply |
Tuesday, September 17, 2013
terms
Thermistor- Small enough to fit on a dime this is a special kind of semiconductor changes electrical resistance with temperature changes.
With increased sensitivity it detects small temperature changes more than an RTD can.
Sensitivity- a device's ability to detect changes in a variable.
The more resolution a device has within a variable range the more that the change in the variable can be detected.
Thermocouple- an arrangement of 2 dissimilar metals in the form of wires joined together at both ends. It detects temperature by generating an electrical voltage.
The difference in voltage measurement of the variable or hot junction to that of the reference or cold junction determines a voltage from which a corresponding known temperature can be found on a chart specifically for that said thermocouple. If millivoltage is between 2 reference temperatures a
calculation* is performed to determine the actual temperature
Calucation involves *Span Math to convert milivoltage to temperature
With increased sensitivity it detects small temperature changes more than an RTD can.
Sensitivity- a device's ability to detect changes in a variable.
The more resolution a device has within a variable range the more that the change in the variable can be detected.
Thermocouple- an arrangement of 2 dissimilar metals in the form of wires joined together at both ends. It detects temperature by generating an electrical voltage.
The difference in voltage measurement of the variable or hot junction to that of the reference or cold junction determines a voltage from which a corresponding known temperature can be found on a chart specifically for that said thermocouple. If millivoltage is between 2 reference temperatures a
calculation* is performed to determine the actual temperature
Calucation involves *Span Math to convert milivoltage to temperature
Thursday, September 5, 2013
Pressure and Level class
PDF of Some Formulas we came up with
These are to convert from psig to psia & vice versa as well as determining inches of water from those.
These are to convert from psig to psia & vice versa as well as determining inches of water from those.
Monday, September 2, 2013
Subscribe to:
Posts (Atom)